Ambene® Visco Uno (Intra-articular agent) Instructions for Use
Marketing Authorization Holder
Promomed Rus LLC (Russia)
Contact Information
PROMOMED RUS LLC (Russia)
Dosage Form
| Ambene® Visco Uno | Intra-articular agent 1%: 2 ml syringes 1 or 2 pcs. |
Dosage Form, Packaging, and Product Composition
Intra-articular agent in the form of a colorless, viscous solution, free from foreign inclusions.
| 1 ml | |
| Sodium hyaluronate | 10 mg |
| Dynamic viscosity >100 mPa·s Molecular mass not less than 3 MDa Osmolality 250-350 mOsm/kg PH 6.5-7.5 |
|
Excipients: physiological phosphate-saline buffer – to a volume of 1 ml.
2 ml – single-use pre-filled syringes with a volume of 2.25 ml (1) – contour cell packaging* (1) – cardboard boxes.
2 ml – single-use pre-filled syringes with a volume of 2.25 ml (1) – contour cell packaging** (2) – cardboard boxes.
* supplied with single-use sterile injection needles 18G 1 1/2 (1.2×38 mm) (1 pc.) and 21G 1 1/2 (0.8×38 mm) (1 pc.), a sticker (1 pc.).
** supplied with single-use sterile injection needles 18G 1 1/2 (1.2×38 mm) (2 pcs.) and 21G 1 1/2 (0.8×38 mm) (2 pcs.), stickers (2 pcs.).
Therapeutic Category
Medical device for the treatment of musculoskeletal system diseases
Properties
The intra-articular agent Ambene® Visco Uno 1% is a synovial fluid prosthesis in pre-filled syringes.
It is used against the background of degenerative changes in the cartilage surface to improve joint mobility, reduce pain, decrease inflammatory reactions, and restore homeostasis in the cartilage.
Ambene® Visco Uno 1% is a sterile, viscous, high molecular weight (molecular mass is not less than 3 MDa) solution of the sodium salt of hyaluronic acid (sodium hyaluronate).
Hyaluronic acid is an essential component of the extracellular matrix, present in high concentrations in cartilage and synovial fluid.
Hyaluronic acid provides viscosity and elasticity to the synovial fluid. Intra-articular injection of hyaluronic acid leads to an improvement in the functional state of the joint.
It prevents friction of the articular surfaces, which helps to eliminate pain and inflammation, and also protects against premature wear and destruction of cartilage, provides mobility, and has shock-absorbing capacity (dampens external shocks, protecting the joint components from damage).
The sodium hyaluronate solution is distributed locally in the joint cavity, where it undergoes local transformations, exerting a lubricating effect.
Extraction or replacement of the agent is not applicable, as it mixes inseparably with the joint synovial fluid.
Based on a review of studies of products with a similar composition, the duration of the therapeutic effect is up to 6 months or more, depending on the injection site, the degree of the disease, and individual characteristics of the body.
Scope of Application
Of the product Ambene® Visco Uno
- To increase joint mobility and eliminate pain caused by osteoarthritis/osteoarthrosis, as well as other degenerative-dystrophic or post-traumatic joint changes;
- For rehabilitation after orthopedic joint surgery and arthroscopy;
- For individuals with increased stress on damaged joints.
ICD codes
| ICD-10 code | Indication |
| M19.9 | Unspecified arthrosis |
| M25.5 | Pain in joint |
Dosage Regimen
| The method of application and dosage regimen for a specific drug depend on its form of release and other factors. The optimal dosage regimen is determined by the doctor. It is necessary to strictly adhere to the compliance of the dosage form of a specific drug with the indications for use and dosage regimen. |
Intra-articularly. The injection regimen for the joints is determined by the doctor individually, taking into account the severity of degenerative or traumatic changes in the joint.
Into the knee joint, the contents of one filled syringe are injected once a week, in a course of up to 5 injections according to the standard technique described below. Usually, for the knee joint, a 21G needle is used; for other joints, it is recommended to use a needle of the required size (from 17 to 22G) depending on the joint.
If necessary, a repeated course of injections can be carried out after consultation with a doctor.
Injection technique
Before the procedure, the patient must be informed about the indications of the medical device, as well as its contraindications and possible undesirable side effects.
Before use, make sure that the packaging of the product is not damaged and sterility is not compromised, and the product’s expiration date has not passed.
Do not reuse. With repeated use, there is a risk of infection or bloodborne contamination. The agent should only be administered by specially trained doctors.
Rules of asepsis and antisepsis must be observed during the procedure. The injection site must be properly disinfected. Disinfectants containing quaternary ammonium compounds should not be used, as hyaluronic acid precipitates in the presence of these substances.
It is recommended to warm the agent to room temperature before use.
The agent should be injected precisely into the joint cavity using standard techniques, taking into account anatomical features. Before administering the agent, effusion (if present) should be removed from the joint capsule. The same needle, inserted once before aspiration, can be used to remove the effusion and administer the agent. In this case, the syringe with the agent is attached to the needle freed from the syringe. To confirm the needle’s location in the joint cavity, a small amount of synovial fluid should be aspirated before slow injection. The introduction of the agent into the joint cavity should be stopped if pain occurs during the injection.
When inserting the needle, especially for injections into the hip joint, the use of local anesthesia is recommended. Air should be avoided entering the syringe.
It is recommended to perform joint injections under ultrasound or fluoroscopic control.
Procedure for working with the syringe
- Open the contour cell packaging under aseptic conditions.
- Unscrew the cap from the syringe tip.
- Firmly attach the needle to the syringe. Screw the needle onto the syringe until it has passed the thread path and is seated tightly.
- Visually ensure that the needle has passed the thread path to the end.
- Remove the cap from the needle with a straight motion. Be careful not to unscrew the needle.
- Expel residual air from the system by holding the syringe barrel with one hand and gently pressing the plunger rod with the other until solution appears at the needle tip.
The solution should be injected slowly, applying minimal necessary pressure.
If the needle becomes blocked, do not increase pressure on the plunger rod. Instead, stop the injection and replace the needle.
Any unused portion of the agent should not be stored.
The biodegradation period of the medical device is up to 6 months or more.
Precautions for use
Do not use Ambene® Visco Uno 1% with damaged or opened packaging.
Avoid inserting the needle into blood vessels during the manipulation.
Side effects
Possible: moderate pain, swelling, increased temperature and redness at the injection site, increased exudate content in the joint cavity. The above symptoms are transient and usually disappear within 24 hours. If these symptoms occur, it is recommended to unload the affected joint and apply ice.
Extremely rarely allergic reactions.
Contraindications
- Hypersensitivity to the components of the agent;
- Presence of infection or skin lesions in the injection area;
- Acute synovitis;
- Children under 18 years of age (due to lack of clinical data).
Use during pregnancy and breastfeeding
It is not recommended to use the agent during pregnancy and breastfeeding due to the lack of clinical data.
Prescription of the agent during pregnancy and breastfeeding is at the discretion of the attending physician.
Special instructions
Sodium hyaluronate is obtained by fermentation of Streptococcus equi bacteria and is thoroughly purified. Nevertheless, the physician should consider the potential risk associated with the injectable administration of any biological substances.
During the first 2 days after the procedure, it is recommended not to overload the joint, especially avoiding prolonged stress.
Ambene® Visco Uno 1% is not prescribed to patients with inflammatory diseases, in particular, Bechterew’s disease and rheumatoid arthritis.
Not intended for children.
For single use only.
The kit includes 2 or 4 (depending on the number of syringes in the package) single-use sterile injection needles to enable the doctor to choose a needle of the required caliber/size depending on the joint into which the agent will be injected. Attention must be paid to the expiration date of the needle indicated on its label.
For safe use and disposal of used needles, national and regional rules and regulations must be observed.
Medical device safety requirements
The agent is non-toxic and does not have a harmful effect on the human body when handled.
The agent does not form toxic compounds in the air or in wastewater and does not lead to sanitary-hazardous environmental pollution.
The agent must meet biological safety requirements in accordance with GOST R 52770 and the GOST ISO 10993 series of standards.
Sterilization information
The components of the agent are pre-mixed and packaged into syringes. The filled syringes are sterilized by steam sterilization in an autoclave in accordance with GOST R ISO 17665-1, GOST R 56893/ISO/TS 17665-2.
Disposal
Used materials are disposed of according to the hazard class specified in SanPiN 2.1.3684.
In accordance with SanPiN 2.1.3684
- The syringe with needles, according to the hazard classification, belongs to Class B;
- Packaging materials, cardboard box, and blister, according to the hazard classification, belong to Class A.
The syringe with needles must be disposed of immediately after use, even if the contents were not used completely.
Effect on the ability to drive vehicles and mechanisms
Ambene® Visco Uno 1% does not affect a person’s ability to drive vehicles, engage in other potentially hazardous activities that require increased concentration and speed of psychomotor reactions.
Drug Interactions
Ambene® Visco Uno 1% should not be prescribed simultaneously with other intra-articular injections.
Disinfectants containing quaternary ammonium compounds should not be used, as hyaluronic acid precipitates in the presence of these substances.
Storage Conditions
The agent should be stored and transported in its packaging at a temperature from +2°C (35.6°F) to +30°C (86°F) and relative air humidity up to 80% in a place protected from direct sunlight, out of the reach of children.
Shelf Life
Shelf life – 36 months. Do not use after the expiration date.
Dispensing Status
Over-the-Counter
Important Safety Information
This information is for educational purposes only and does not replace professional medical advice. Always consult your doctor before use. Dosage and side effects may vary. Use only as prescribed.
Medical Disclaimer